110 kV power transformers with on-load tap changers, 6.3 – 63 MVA
Two- and three-winding oil-immersed power transformers for 110 kV substations, with on-load tap changing as standard, cooling to ONAN / ONAF / OFAF, and routine test records issued with every unit — third-party type testing arranged to your specification.

Technical specification
Typical values. Confirm the exact figures for your project in the enquiry — impedance, loss limits and insulation levels are usually dictated by your tender.
| Rated power | 6.3 MVA – 63 MVA |
|---|---|
| Voltage class | 110 kV (equipment level 123 kV) |
| Winding | Two-winding or three-winding |
| Cooling | ONAN / ONAF / OFAF, to load profile |
| Tap changer | On-load (OLTC), ±8 × 1.25 % typical |
| Vector group | YNd11 standard; YNyn0d11 and others on request |
| Impedance | 10.5 % typical, to customer specification |
| Core | CRGO silicon steel, 45° step-lap mitred joints |
| Insulation level | LI 480 kV / AC 200 kV (110 kV class) |
| Losses | To IEC 60076-20 or your tender’s evaluation formula |
| Standards | IEC 60076, GB 1094; IEEE C57 on request |
| Testing | Routine tests in our own works on every unit; third-party type test at an accredited laboratory on request |
| Standard lead time | 60 days from approved drawing — the build is slower at this insulation level, and a third-party type test, if specified, is booked inside this figure |
| Multi-unit and project orders | Scheduled in the quotation, against the delivery date you give us |
The unit itself
Photographed in our own works before packing — no stock images, no renders standing in for a product we do not build.



Design points that matter on site
Each of these comes from problems customers brought to us after buying elsewhere.
On-load tap changing as standard
OLTC fitted as the default configuration, so voltage correction happens under load rather than requiring an outage.
Type testing arranged to your requirement
Routine tests — ratio, resistance, impedance, losses, applied and induced voltage — are carried out in our own works on every unit, and the records travel with the transformer. For 110 kV units a third-party type test at an accredited laboratory can be reserved as part of the order; the report is issued directly to you. Tell us at enquiry stage whether your consultant requires it witnessed, because it changes the delivery slot.
Transport and site conditions planned up front
Above 40 MVA, transport weight and route clearances usually decide the design. We confirm shipping constraints before the drawing is frozen.
Loss evaluation taken seriously
Core and winding geometry optimised to whichever loss capitalisation formula your tender applies, with calculated figures supplied in the bid.
Typical applications
- 110 kV substations
- Utility transmission and distribution
- Industrial main substations
- Renewable energy grid connection
Delivered to projects across the Middle East and Africa. Reference lists are available on request.